Equipment performance measured against its own expected behaviour.
Arvane models what each asset should draw for the duty it is delivering, and tracks the gap between expected and observed performance under comparable conditions.
Expected against observed, under comparable conditions.
- THE PROBLEM
- Equipment degrades gradually. A compressor, pump or fan can keep delivering its duty while drawing more power each month, until the loss becomes part of the normal profile.
- WHAT ARVANE ANALYZES
- Power and fuel input against delivered duty (flow, pressure, load, throughput), together with runtime, operating state, ambient conditions and maintenance history.
- WHAT THE TEAM RECEIVES
- An expected-performance baseline for each modelled asset, the size and persistence of any deviation, and a ranked list of assets for investigation.
- WHY IT MATTERS
- Degradation costs energy before it costs availability. Seeing it early gives maintenance planners evidence to schedule work where it matters most.
Four steps, each one open to review.
Every step records what it used and what it assumed, so an engineer can check the result rather than take it on trust.
- 01
Characterize the duty
Identify the variables that define the work an asset does: flow, pressure, load or throughput.
- 02
Build the baseline
Model expected energy input for that duty from healthy operating history, informed by equipment curves where available.
- 03
Track the deviation
Compare observed with expected at equivalent conditions, and record the size and persistence of any gap.
- 04
Rank for investigation
Order assets by deviation, persistence and energy at stake, with maintenance history attached.
A fixed threshold identifies a high reading. A performance baseline asks whether the reading is right for the load, product, ambient conditions and equipment state. Meter quality, production changes and recent maintenance are checked before a deviation is attributed to the asset.
- 01Degradation
- 02More energy per unit of duty
- 03Higher cost
- 04Higher carbon
- 05Failure risk
TYPICAL INPUTS
- Asset power or fuel input
- Flow, pressure, load and throughput
- Runtime and operating state
- Ambient conditions
- Condition monitoring
- Work orders and maintenance history
Which sources are connected is agreed for each site during scoping.
QUESTIONS IT ANSWERS
- Which assets are drawing more energy for the same duty?
- Is this deviation new, or has it been building since the last service?
- Where would maintenance recover the most energy?
Discuss asset performance for your operation.